Managing Fire Risk in Buildings with Multiple Occupiers
A practical guide to coordinating fire risk assessments, shared responsibilities, fire protection systems and emergency arrangements in multi-occupied commercial and mixed-use buildings.
Managing fire risk in buildings with multiple occupiers requires more than installing fire alarms, providing extinguishers and displaying evacuation notices. It involves coordinating different organisations, understanding shared responsibilities, controlling activities that may introduce fire hazards and ensuring that everyone can respond effectively during an emergency.
Commercial buildings, office complexes, shopping centres, industrial units, mixed-use developments and multi-tenanted properties frequently contain several independent organisations operating within one structure. Each occupier may have different working hours, equipment, storage arrangements, employee numbers and emergency procedures. However, they may all depend on the same corridors, staircases, fire alarm infrastructure and building management systems.
This creates an important management challenge: an activity undertaken by one tenant can affect the safety of people working or living in another part of the building. For example, a contractor carrying out hot work in one unit may introduce an ignition risk, while a blocked shared corridor can compromise evacuation for every occupier using that route.
Effective fire safety therefore depends on a coordinated, whole-building approach. Individual occupiers must understand their own responsibilities while communicating with landlords, managing agents and other responsible persons about risks that could affect the wider premises.
It involves identifying hazards throughout the premises, coordinating individual fire risk assessments, establishing clear responsibilities, maintaining shared fire protection systems, protecting common escape routes and implementing consistent emergency arrangements. Every responsible person must understand how their activities and precautions affect other building users.
1. Understanding the Challenges of Managing Fire Risk in Buildings with Multiple Occupiers
Multi-occupancy buildings present a different fire safety management challenge from single-occupier premises. In a single business environment, management may have direct control over most activities, staff procedures, maintenance arrangements and building access. In a shared building, responsibility and control can be distributed between several organisations.
For example, a commercial office building may contain a property management company, several independent businesses, cleaning contractors, maintenance providers and security personnel. Each party may control different areas, but the building’s fire safety arrangements remain interconnected.
Different occupancies create different fire risks
The nature of the activities taking place in each unit influences the type and level of fire risk. An office may contain computers, printers, electrical distribution equipment and furniture. A restaurant may introduce cooking equipment, extraction systems, oils and combustible packaging. A warehouse may store large quantities of combustible materials, while a residential section may contain sleeping occupants who need different warning and evacuation arrangements.
These differences must be considered when developing an overall building fire safety strategy. A system that is suitable for one occupancy may not automatically be suitable for another. Management must understand the interaction between individual activities and shared protection arrangements.
Shared building infrastructure
Several tenants may depend on common fire detection systems, alarm control panels, emergency lighting, smoke control equipment, fire doors and protected staircases. A fault, unauthorised modification or maintenance failure affecting one shared system may have consequences throughout the premises.
For example, a tenant arranging electrical work could accidentally affect an alarm circuit. Similarly, a contractor installing new services might penetrate a fire-resisting wall without restoring its original protective performance. These problems demonstrate why building alterations and maintenance activities require proper coordination.
Different working hours and occupancy patterns
Some organisations operate during normal office hours, while others remain open overnight, work weekends or operate on rotating shifts. Residential occupiers may be present when commercial areas are closed. Cleaning and maintenance contractors may work when most tenants are absent.
These occupancy patterns affect alarm response, emergency communication, supervision and evacuation arrangements. Building management should establish how emergency procedures operate outside normal business hours and whether nominated personnel are available when required.
Commercial office buildings
Electrical equipment, office furniture, kitchen facilities, temporary electrical connections and changing employee numbers require ongoing attention.
Retail and shopping premises
Customer movement, stock storage, displays, deliveries, public access and shared shopping areas can complicate fire prevention and evacuation.
Industrial and warehouse units
Machinery, combustible storage, battery charging, flammable materials, hot work and vehicle movements may increase fire risk.
Mixed-use developments
Residential, retail, leisure and commercial activities may have different occupancy patterns, escape requirements and fire safety arrangements.
Why a whole-building approach is necessary
One of the most significant problems in multi-occupancy premises is treating each tenancy as an isolated environment. A tenant may have a suitable internal evacuation procedure but still depend on a shared staircase that is poorly maintained or obstructed. Another occupier may maintain its own equipment correctly while failing to notify building management about a change in process that affects the common fire strategy.
A whole-building approach connects these individual arrangements. It establishes communication channels, identifies shared risks, coordinates maintenance and ensures that the building’s emergency arrangements work as a coherent system.
2. Identifying Common Fire Hazards in Multi-Occupancy Buildings
Identifying common fire hazards is an essential part of managing fire risk in buildings. The assessment must consider hazards inside individual tenancies as well as those found in communal areas, plant rooms, service spaces and external areas.
A fire hazard is anything with the potential to start a fire or contribute to its development. In multi-occupancy buildings, hazards may arise from routine business activities, temporary work, poor housekeeping, electrical faults or inadequate building maintenance.
Electrical equipment and installations
Electrical equipment is present in almost every type of commercial premises. Computers, kitchen appliances, industrial machinery, chargers, extension leads, lighting equipment and distribution boards can all introduce ignition risks if incorrectly installed, damaged, overloaded or poorly maintained.
Building managers should establish suitable arrangements for reporting electrical defects and coordinating work on shared electrical installations. Tenants should ensure that equipment used within their premises is appropriate for the task and maintained in a safe condition.
Combustible materials and poor housekeeping
Packaging, paper, cardboard, furniture, textiles, waste materials and stock can provide fuel for a fire. In shared buildings, these materials may accumulate in storage rooms, service areas, corridors and loading bays.
Tenants should maintain suitable storage arrangements, remove unnecessary waste and prevent combustible materials from accumulating near ignition sources. Shared waste collection areas should also be managed so that rubbish does not obstruct access or create an avoidable fire hazard.
Cooking and heating equipment
Restaurants, staff kitchens, catering units and hospitality businesses may use cooking appliances, extraction systems, heating equipment and other sources of high temperatures. These activities require appropriate operational controls, cleaning and maintenance.
Building management should understand whether tenant activities create risks for adjacent premises, particularly where ventilation systems, service ducts or building voids are shared.
Contractor activities and hot work
Construction, welding, cutting, grinding, roofing and maintenance activities can introduce temporary ignition sources. These activities are particularly important in occupied buildings because contractors may work near combustible materials, concealed spaces or fire-resisting construction.
A permit-to-work arrangement may be appropriate for higher-risk work. Depending on the activity, controls can include authorisation, removal or protection of combustible materials, isolation of relevant equipment, suitable firefighting provisions and post-work fire monitoring.
Smoking, arson and external hazards
Smoking materials, deliberate ignition, poorly controlled external waste storage and unsecured building access can also contribute to fire risk. Waste containers placed against external walls or near openings may create opportunities for fire to affect the building.
Fire doors, service penetrations and concealed spaces
Fire doors and fire-resisting construction help restrict the movement of fire and smoke. Damage, missing seals, defective self-closing devices, unauthorised alterations and unsealed service penetrations can reduce their effectiveness.
Maintenance teams and tenants should report damaged fire doors and suspected breaches in fire-resisting construction. Repairs should use appropriate systems and competent contractors rather than improvised materials.
Common hazards and recommended controls
| Fire hazard | Potential consequence | Recommended management control |
|---|---|---|
| Electrical faults | Ignition and fire development | Appropriate inspection, maintenance and defect reporting. |
| Combustible storage | Increased fire load and rapid fire growth | Controlled storage and regular housekeeping inspections. |
| Hot work | Ignition of nearby combustible materials | Risk assessment, authorisation and suitable hot-work controls. |
| Blocked corridors | Delayed or obstructed evacuation | Routine inspections and immediate obstruction removal. |
| Damaged fire doors | Increased smoke and fire spread | Reporting, inspection and competent repair. |
| Unauthorised alterations | Compromised fire separation or systems | Building change-control and approval procedures. |
| Defective alarms | Delayed fire warning | Testing, maintenance and fault escalation. |
3. Conducting Effective Fire Risk Assessments in Shared Buildings
A fire risk assessment is a structured evaluation of the potential causes of fire, people who could be harmed, existing precautions and additional measures needed to control risk. In a multi-occupancy building, the process must consider both individual occupier activities and the shared areas and systems on which everyone depends.
Each responsible person should assess the premises and activities for which they have responsibility. Where several responsible persons share a building, their assessments and arrangements must be coordinated so that important risks are not overlooked between tenancy boundaries.
The Home Office’s Fire Safety Risk Assessment: Offices and Shops guidance is a useful reference for relevant office and retail environments in England. It also explains the importance of coordination where individual units form part of a larger complex.
Step 1: Establish the building’s occupancy profile
Begin by identifying how the building is used. Record the number and type of occupiers, business activities, operating hours, employee numbers, visitor patterns and any particularly high-risk processes.
Information should also cover contractors, delivery personnel, cleaning staff and other people who may be present temporarily. The building manager should maintain an accurate occupancy and contact register, with suitable arrangements for updating it whenever a tenancy changes.
Step 2: Identify hazards in each area
Inspect individual premises, common corridors, staircases, plant rooms, storage areas, loading bays and external spaces. Identify ignition sources, combustible materials, oxygen sources and conditions that could allow fire or smoke to spread.
Where access to a tenant’s premises is controlled by another organisation, establish appropriate inspection and information-sharing arrangements. The assessment should not assume that areas outside the building manager’s direct control are automatically free from hazards.
Step 3: Identify people at risk
Consider employees, customers, residents, visitors, contractors and members of the public. Particular attention should be given to people who may need additional assistance or more time to evacuate.
Assessments should consider mobility limitations, sensory impairments, unfamiliarity with the building, language barriers, lone working and periods when staffing levels are reduced. Suitable arrangements should be developed according to the actual needs of the people using the premises.
Step 4: Evaluate existing fire precautions
Review the suitability and condition of fire detection, alarm systems, emergency lighting, fire doors, escape routes, compartmentation and other protective measures. Determine whether they are appropriate for the building’s current occupancy and activities.
Check that the fire safety arrangements within individual tenancies do not conflict with shared systems or the building’s overall evacuation strategy. Where shortcomings are identified, establish corrective actions and responsible persons.
Step 5: Record findings and establish an action plan
Document significant findings, existing controls, deficiencies, required improvements, responsible individuals and target completion dates. In complex premises, a building-level action register can help coordinate issues that affect several occupiers.
Prioritise actions according to the severity and urgency of the risk. An immediate escape-route obstruction should not be treated in the same way as a minor administrative improvement that can be completed through routine management.
Step 6: Review and update assessments
Fire risk assessments should remain under review and be revised when they are no longer valid or significant changes affect fire safety. Examples include a new tenant, changes in building use, refurbishment, alterations to escape routes, new hazardous materials or failure of important protection systems.
Changes in occupancy can be especially important. A unit previously used as a low-risk office may become a restaurant, workshop or storage facility. The new activity could introduce hazards that affect adjacent occupiers and the wider building.
What should a shared-building fire risk assessment cover?
- Building layout, occupancy types and tenant activities.
- Ignition sources, combustible materials and dangerous substances.
- People who may require additional evacuation support.
- Common corridors, staircases and final exits.
- Fire doors, compartmentation and concealed service routes.
- Fire alarm, detection and emergency lighting arrangements.
- Contractor activities and building alteration controls.
- Communication between responsible persons.
- Emergency procedures, training and maintenance.
- Review dates, corrective actions and management records.
For more advanced professional knowledge, explore the ICTQual Level 3 Diploma in Fire Risk Assessor, which is relevant to learners developing knowledge of fire risk assessment practice.
4. Responsibilities of Landlords, Building Managers and Multiple Occupiers for Fire Safety
Clear responsibility arrangements are fundamental to managing fire risk in buildings with multiple occupiers. The fact that a building contains several tenants does not mean that fire safety obligations can simply be transferred to one central management company.
In England and Wales, the Regulatory Reform (Fire Safety) Order 2005 establishes duties for responsible persons in relevant non-domestic premises. A responsible person may be an employer, the person controlling premises or another person identified under the Order, depending on the circumstances.
The GOV.UK guidance on who is responsible for workplace fire safety explains that employers, owners, landlords, occupiers and people with control of premises may have responsibilities. More than one responsible person can exist within the same building.
Responsibilities of landlords and property owners
Landlords and owners should understand which parts of the premises they control and the extent of their fire safety duties. Depending on the property arrangements, these may include shared corridors, staircases, entrances, plant rooms, external areas and structural fire safety features.
Typical management responsibilities may include:
- Arranging appropriate fire risk assessments for areas under their control.
- Maintaining relevant shared fire safety precautions.
- Providing tenants with important fire safety information.
- Establishing procedures for reporting defects and hazards.
- Coordinating building maintenance and contractor activities.
- Managing changes that could affect the building’s fire safety arrangements.
- Working with other responsible persons to coordinate precautions.
Responsibilities of building managers and managing agents
Building managers and managing agents may have responsibilities where they exercise control over relevant premises or activities. Their role often involves coordinating operational arrangements between landlords, tenants, contractors and specialist service providers.
They should maintain accurate contact information, communicate significant risks, monitor shared facilities and ensure that faults are escalated to the appropriate person. They should also maintain records of inspections, testing, maintenance and outstanding actions within their area of responsibility.
Responsibilities of tenants and occupiers
Occupying organisations must understand their own fire safety duties. They should assess the risks arising from their business activities, protect employees and visitors, maintain relevant precautions and communicate information that could affect other occupiers.
Tenants should also:
- Maintain suitable housekeeping and storage arrangements.
- Keep escape routes within their control available and unobstructed.
- Report defects involving shared systems or building structures.
- Notify management about significant changes in activities.
- Provide appropriate fire safety information and training to employees.
- Coordinate emergency procedures with the wider building strategy.
- Ensure contractors comply with relevant building procedures.
The importance of Article 22: cooperation and coordination
Article 22 of the Regulatory Reform (Fire Safety) Order 2005 is particularly important in shared premises. It requires responsible persons who share or have duties in respect of premises to cooperate and coordinate their fire safety measures and share information about relevant risks.
Following amendments effective from 1 October 2023, responsible persons must also take reasonable steps to establish whether other responsible persons share or have duties in respect of the premises. They must exchange relevant identification and contact information, identify the parts of the premises for which they consider themselves responsible and keep a record of that information.
Read the current wording of Article 22 of the Fire Safety Order for the legal requirements.
| Party | Typical area of control | Management priority |
|---|---|---|
| Landlord or owner | Building fabric and areas under their control | Ensure relevant building-level precautions are maintained. |
| Managing agent | Managed operations and contracted services | Coordinate communication, inspections and corrective actions. |
| Tenant or employer | Occupied business premises and work activities | Control operational hazards and protect employees and visitors. |
| Facilities manager | Specific facilities and systems under their control | Maintain systems and escalate defects appropriately. |
| Contractor | Authorised work activities | Follow work controls and report risks introduced by the work. |
5. Managing Fire Safety in Shared Areas and Common Escape Routes
Common areas are among the most important parts of a multi-occupancy building’s fire safety arrangements. Corridors, staircases, lobbies, entrances and shared access routes may serve several organisations at the same time. If these areas become unsafe or inaccessible, the consequences can affect the entire building.
Effective management requires clear ownership, regular inspections, suitable maintenance and consistent rules for every occupier.
Keeping shared escape routes unobstructed
Escape routes should remain available for their intended purpose. Tenants should not use shared corridors, staircases or lobbies for storing deliveries, packaging, furniture, waste or business equipment.
Building management should establish clear procedures for identifying and removing obstructions. Regular inspections should be documented, and repeated breaches should be escalated to the relevant occupier.
Escape routes must be suitable for the number and characteristics of people expected to use them. Their availability should not depend on access through another tenant’s premises unless the arrangement has been properly assessed and secured.
Maintaining fire doors and compartmentation
Fire doors help protect escape routes and limit the spread of smoke and fire when correctly installed, maintained and used. Shared buildings often have fire doors separating tenant areas, common corridors, staircases and service rooms.
Management arrangements should cover inspection, defect reporting, suitable repairs and the prevention of unauthorised modifications. Occupiers should not wedge fire doors open or remove self-closing devices for convenience.
Similarly, walls, floors, ceilings and service penetrations may form part of the building’s fire-resisting construction. Any contractor work that affects these elements should be assessed and properly controlled.
Read our Passive Fire Protection Guide to understand how fire-resisting construction, compartmentation and other passive measures contribute to building safety.
Shared alarm systems and emergency lighting
Some multi-occupancy buildings use common fire detection and alarm systems. Management should establish how the system operates, which areas it covers, how faults are reported and who is authorised to arrange maintenance.
Tenants must understand the building’s warning arrangements and should not alter shared alarm equipment without appropriate authorisation. Any proposed work that could affect detection, warning or communication must be coordinated with the relevant parties.
Emergency lighting should also be maintained according to the system design and applicable requirements. Its purpose is to help people identify escape routes and move towards safety when normal lighting fails.
Our guide to Fire Alarm Systems provides further information about detection, warning and system management.
Managing loading bays, service rooms and external spaces
Fire safety management should extend beyond internal corridors. Loading areas, waste storage points, plant rooms, external access routes and delivery spaces can create additional risks.
Waste containers should be positioned and managed appropriately. Plant rooms should remain secure and free from unauthorised storage. Emergency vehicle access should be maintained, and deliveries should not interfere with designated escape routes or emergency access arrangements.
Establishing a shared inspection programme
A planned inspection programme helps identify defects before they become more serious. The frequency and depth of checks should be determined by the building’s risk profile, the nature of the systems and the relevant maintenance requirements.
Routine visual checks
Check common corridors, staircases, final exits, visible fire doors, housekeeping and access to firefighting equipment.
Planned system maintenance
Arrange appropriate inspection, testing and maintenance of alarms, emergency lighting, smoke control and other protective systems.
Defect reporting
Record faults, identify the responsible person, establish interim precautions where necessary and track repairs to completion.
Tenant communication
Inform occupiers about shared-area restrictions, planned maintenance, temporary access changes and significant fire safety issues.
6. Developing Effective Fire Evacuation Plans and Emergency Procedures
An effective evacuation plan must reflect the building’s actual layout, occupancy profile and fire safety strategy. In multi-occupancy premises, it is not sufficient for each tenant to create a separate emergency procedure without considering how it interacts with the arrangements for other parts of the building.
The responsible persons should cooperate to ensure that their procedures are consistent with the overall fire safety arrangements and that people understand what to do when an alarm is raised.
Establishing a coordinated evacuation strategy
Building management should ensure that the evacuation arrangements are appropriate for the premises and the people using them. Depending on the building design, fire strategy and risk assessment, different arrangements may be necessary for different areas.
The strategy must be based on the actual fire safety design and assessment. A stay-put strategy, for example, may be relevant to certain purpose-built residential buildings with suitable compartmentation, but it should never be assumed to apply to every multi-occupied property.
Commercial tenants must understand whether the building uses simultaneous evacuation, phased evacuation or another approved arrangement. Their internal procedures must support, rather than contradict, the building’s strategy.
Communicating alarm procedures
Everyone should understand how to recognise the fire warning, which actions to take and where to go. Instructions should be accessible, understandable and appropriate for employees, customers, residents, contractors and visitors.
Building management should explain the alarm arrangements to new occupiers and provide updates whenever systems or procedures change. Tenants should ensure that employees receive appropriate induction and refresher information.
Planning for people requiring assistance
Some individuals may require additional assistance or alternative arrangements to evacuate safely. These may include people with mobility limitations, visual or hearing impairments, temporary injuries or other circumstances that affect their ability to respond.
Arrangements should be based on individual needs, the building’s design and the emergency strategy. Where appropriate, personal emergency evacuation arrangements should be developed and coordinated with the relevant building management and responsible persons.
Refuges, evacuation equipment, communication systems and assistance procedures should only be relied upon where they are appropriate, available and properly managed.
Managing visitors, contractors and temporary workers
Visitors may not know the building layout or the location of emergency exits. Tenants should provide appropriate instructions and ensure that visitors understand what to do when the alarm sounds.
Contractors should receive relevant site-specific information before work begins. Where work takes place outside normal hours, arrangements should be made to ensure that emergency instructions remain available and that suitable supervision and communication are maintained.
Conducting coordinated fire drills
Fire drills help assess whether people understand the evacuation arrangements and whether the procedures work in practice. In a shared building, the need for coordination should be considered when planning drills, especially where several tenants depend on the same alarm system or escape routes.
Drills should be planned according to the building’s strategy and the applicable requirements. Their findings should be recorded and used to improve training, communication and emergency arrangements.
Information to include in an emergency plan
- How to raise the alarm and report a fire.
- What occupants should do when a warning is received.
- Which evacuation routes and exits are available.
- Where people should assemble, where applicable.
- How visitors and contractors will be informed and assisted.
- Arrangements for people requiring additional evacuation support.
- Who contacts the fire and rescue service.
- How building management communicates emergency information.
- What happens when normal access routes or systems are unavailable.
- How emergency arrangements are reviewed after an incident or drill.
7. Fire Prevention, Compartmentation and Protection Measures in Multi-Occupancy Buildings
Effective fire prevention and protection require a combination of organisational controls, building design features and maintained fire safety systems. Multi-occupancy premises need these measures to work together because fire or smoke originating in one unit may affect people in other parts of the building.
Fire prevention through operational controls
Preventing a fire from starting is the first priority. Tenants should maintain suitable housekeeping, control ignition sources, store combustible materials appropriately and ensure that equipment is used safely.
Building managers should introduce procedures for activities that could affect other occupiers. These may include hot work, electrical maintenance, temporary equipment installation, deliveries and refurbishment.
Clear reporting procedures are equally important. Employees and contractors should know how to report electrical defects, damaged equipment, unusual smells, overheating and unsafe storage conditions.
Passive fire protection and compartmentation
Passive fire protection consists of building features designed to restrict the spread of fire and smoke. These may include fire-resisting walls, floors, ceilings, fire doors, cavity barriers and appropriately protected service penetrations.
Compartmentation divides a building into sections that help limit fire and smoke spread. It is especially important in mixed-use and multi-tenant buildings where different activities take place in adjoining areas.
Compartmentation can be undermined when contractors install cables, pipes or ventilation services through protected walls and floors without providing suitable fire-stopping. Building management should maintain records of relevant alterations and ensure that appropriate systems are used to reinstate fire resistance.
Learn more through our guide to passive fire protection.
Active fire protection systems
Active fire protection measures detect, warn about or help control a fire. Depending on the premises and its fire strategy, these may include:
- Automatic fire detection systems.
- Manual fire alarm call points and warning devices.
- Automatic sprinkler installations.
- Smoke detection and smoke control systems.
- Emergency lighting and escape signage.
- Appropriate portable firefighting equipment.
Not every system is required in every building. The appropriate precautions depend on the building design, occupancy, risk assessment and applicable standards and requirements.
Maintaining fire detection and alarm arrangements
Where a common fire alarm system serves multiple occupiers, its operation should be understood by everyone who relies on it. Management should know who is responsible for routine testing, specialist maintenance, fault reporting and coordinating any temporary impairment.
Tenants should not assume that a shared alarm system is functioning correctly simply because equipment is visible in their premises. They should know how to report faults and obtain relevant information about the building’s warning arrangements.
Controlling impairment of fire safety systems
Maintenance and refurbishment can sometimes require temporary isolation of alarms, detectors, sprinklers or other protective systems. These activities should be planned and authorised appropriately.
Management should establish which areas will be affected, how long the impairment will last and what temporary precautions are necessary. Relevant occupiers should be informed, and the system should be restored and checked as required before normal arrangements resume.
Managing building changes and refurbishment
Changes to partitions, ceilings, doors, ventilation systems, electrical installations and tenant layouts can affect fire safety. A refurbishment project should therefore include an assessment of its impact on the building’s fire precautions.
Contractors should receive appropriate instructions about fire doors, compartmentation, escape routes, alarm isolation and the handling of combustible materials. Any changes should be reviewed and recorded so that future assessments are based on accurate information.
Our article on how changes in building use can affect fire risk explains why alterations in occupancy and business activities require careful review.
8. Best Practices for Managing Fire Risk in Buildings with Multiple Occupiers
Long-term fire safety performance depends on consistent management rather than occasional inspections or one-time assessments. Buildings with several occupiers need a clear management structure that connects tenants, landlords, managing agents, contractors and other relevant parties.
The following practices can help improve the consistency, accountability and effectiveness of fire safety arrangements.
1. Establish a clear responsibility matrix
Prepare a responsibility matrix showing who manages each relevant area, system and activity. Include common parts, individual tenancies, fire alarms, emergency lighting, fire doors, contractor activities and evacuation arrangements.
Record areas where responsibilities overlap. Where several parties have duties, establish how they will cooperate and coordinate their precautions.
2. Maintain a central fire safety information register
Keep relevant information organised in a central management system. This should include current risk assessments, contact details, inspection reports, maintenance records, training information and outstanding corrective actions.
Each occupier should know how to access information relevant to its responsibilities and how to report a significant fire safety concern.
3. Introduce regular tenant communication
Communication should be continuous rather than limited to the beginning of a tenancy. Building managers can use scheduled meetings, written updates and established reporting channels to inform occupiers about changes, maintenance, hazards and emergency arrangements.
Tenants should promptly communicate significant changes in business activities, occupancy, storage and equipment that could affect fire safety elsewhere in the building.
4. Use a formal contractor management process
Contractors can introduce new hazards through construction, maintenance and repair work. Establish a procedure for authorising work, communicating site risks and controlling activities such as hot work, electrical isolation and work affecting fire-resisting construction.
Verify that relevant precautions are in place before work begins and that affected fire safety systems are restored and checked after completion.
5. Monitor fire safety performance
Building management should review inspection findings, system faults, maintenance delays, repeated tenant breaches and corrective actions. Performance monitoring can reveal recurring problems that may not be apparent from individual inspections.
Useful management indicators include:
- Outstanding high-priority fire safety actions.
- Overdue inspections and maintenance activities.
- Reported defects involving fire doors and escape routes.
- Fire alarm faults and system impairments.
- Tenant communication and training completion.
- Fire drill observations and corrective actions.
- Unapproved alterations and changes in building use.
6. Review fire safety arrangements when tenants change
Tenant turnover is a significant opportunity for management to check whether the building’s fire safety information remains accurate. Before a new occupier begins operating, management should establish the intended use of the space and identify any changes that could affect the building.
The new tenant should receive relevant information about alarm arrangements, escape routes, shared facilities, reporting procedures and the building’s emergency strategy.
7. Invest in competent fire safety management
Buildings with complex layouts, mixed occupancy or higher-risk activities may require specialist support. The appropriate level of competence depends on the complexity of the premises and the nature of the work being undertaken.
Responsible persons should ensure that anyone carrying out a fire risk assessment or specialist fire protection work has suitable knowledge, experience and competence for the task.
For professionals seeking to develop more advanced fire risk assessment knowledge, the ProQual Level 5 Diploma in Fire Risk Assessment is a relevant professional development option.
8. Develop a continuous improvement culture
Fire safety management should evolve as the building and its occupants change. Lessons from inspections, near misses, incidents, drills and maintenance activities should be used to improve procedures.
Managers should encourage tenants to report hazards without delay and ensure that concerns are investigated. A shared commitment to prevention and communication is more effective than relying solely on contractual requirements or periodic inspections.
Practical multi-occupancy fire safety management checklist
The following checklist can help building owners and managers review the main components of their arrangements. It is a management aid, not a substitute for a suitable and sufficient fire risk assessment.
- All relevant responsible persons have been identified.
- Contact information and areas of responsibility are recorded.
- Individual and building-level risk assessments are coordinated.
- Tenant activities and changes in occupancy are monitored.
- Common escape routes remain clear and accessible.
- Fire doors and compartmentation defects are reported and addressed.
- Shared fire alarms and emergency lighting are maintained.
- Contractor work is assessed and appropriately controlled.
- Emergency procedures are consistent across the building.
- People requiring additional evacuation support are considered.
- Fire safety information is shared with relevant occupiers.
- Inspections, training, drills and maintenance are documented.
- Outstanding corrective actions are monitored to completion.
- Fire risk assessments are reviewed following significant changes.
Choosing appropriate professional fire safety training
Fire safety knowledge is important for landlords, facilities managers, property professionals, safety officers and individuals responsible for managing shared premises. Suitable professional development can help people understand fire hazards, risk assessment methods, protective systems and the importance of coordinating safety arrangements.
Depending on experience and professional objectives, relevant options include:
Fire Safety for Managers
Develop practical knowledge of workplace fire safety responsibilities, management procedures and preventative arrangements.
Explore QualCert Level 3 Award in Fire Safety for ManagersProfessional Fire Risk Assessment
Develop more advanced knowledge relevant to the assessment and management of fire risks in different types of premises.
Explore ProQual Level 5 Diploma in Fire Risk AssessmentDevelop Your Professional Fire Safety Knowledge
Explore professional fire safety and risk assessment qualifications designed to support knowledge development in workplace safety, fire prevention and risk management.
Explore All Qualifications Explore Fire Risk Assessor QualificationFrequently Asked Questions About Managing Fire Risk in Buildings with Multiple Occupiers
1. What is managing fire risk in buildings with multiple occupiers?
Managing fire risk in buildings with multiple occupiers involves identifying hazards, assessing risks, coordinating responsible persons and maintaining appropriate fire protection arrangements. It also requires effective communication between landlords, building managers and tenants. The objective is to protect everyone who uses the premises through a coordinated approach to prevention and emergency management.
2. Who is responsible for fire safety in a multi-occupancy building?
Responsibility depends on the person’s role, employment relationship and control of the premises. Landlords, employers, tenants, managing agents and other parties may have duties under applicable fire safety legislation. Where several responsible persons share premises, they must cooperate and coordinate their fire safety arrangements.
3. Does every tenant need a separate fire risk assessment?
Each responsible person must assess the fire risks associated with the premises and activities for which they are responsible. In a multi-occupancy building, tenant assessments should consider relevant shared systems, common escape routes and risks arising from other occupiers. Individual assessments should complement the wider building fire safety arrangements.
4. What is Article 22 of the Regulatory Reform (Fire Safety) Order 2005?
Article 22 concerns cooperation and coordination between responsible persons who share or have duties in respect of premises. It requires relevant parties to cooperate, coordinate their fire safety measures and share information about risks. Amendments effective from October 2023 also introduced requirements concerning identification, contact information and records of areas of responsibility.
5. How can building managers coordinate fire safety between tenants?
Building managers can establish a responsibility matrix, maintain updated tenant contact details and organise regular communication. They should coordinate risk assessments, contractor activities, shared system maintenance and evacuation arrangements. A central fire safety register also helps track inspections, defects and corrective actions.
6. What are the most common fire hazards in multi-occupancy buildings?
Common hazards include electrical faults, combustible storage, cooking equipment, hot work, smoking materials, defective fire doors and obstructed escape routes. Building alterations and contractor activities can introduce additional risks. Regular inspections and communication between occupiers help identify and control these hazards.
7. How should shared fire escape routes be managed?
Shared escape routes should remain suitable, accessible and unobstructed. Building management should establish inspection and defect-reporting procedures, while tenants must ensure that their activities do not compromise common routes. Fire doors, emergency lighting, exit signage and final exits should be maintained as appropriate to the building’s fire strategy.
8. How often should fire risk assessments be reviewed in shared buildings?
Fire risk assessments should be kept under regular review and revised when they are no longer valid or significant changes affect fire safety. Examples include new tenants, changes in business activities, building alterations, changes in occupancy and failures of protective systems. The review frequency should reflect the nature and complexity of the premises.
9. What should happen if a tenant introduces a higher-risk activity?
The tenant should assess the new activity and communicate relevant risks to other responsible persons. Building management should consider whether the change affects shared escape routes, fire protection systems, compartmentation or the wider evacuation strategy. Additional controls may be necessary before the new activity begins.
10. Why is compartmentation important in multi-occupancy buildings?
Compartmentation helps restrict the spread of fire and smoke between different parts of a building. It is particularly important where several tenants or occupancy types share the same structure. Fire-resisting walls, floors, doors and properly sealed service penetrations all contribute to maintaining the intended level of separation.
11. Are landlords responsible for tenant fire safety arrangements?
Landlords are responsible for the fire safety duties arising from their control of relevant premises, but tenants may have their own responsibilities for occupied business areas and activities. The exact duties depend on the circumstances and applicable legislation. Both parties should coordinate their arrangements rather than assume that one automatically replaces the other’s responsibilities.
12. What training is useful for people managing multi-occupancy fire safety?
Useful training may cover fire risk assessment, fire safety management, emergency planning, fire prevention and the maintenance of fire precautions. Building managers and responsible persons should select training appropriate to their duties and the complexity of the premises. Specialist assessments and technical work should be undertaken by suitably competent professionals.
Conclusion: Building a Coordinated Approach to Fire Risk Management
Managing fire risk in buildings with multiple occupiers requires clear responsibilities, effective communication and a coordinated approach to prevention, assessment and emergency planning. Every organisation operating within a shared building must understand how its activities affect other people and how its arrangements connect with the wider fire safety strategy.
Landlords, managing agents, employers, tenants and contractors all have important roles to play within their respective areas of responsibility. Maintaining shared escape routes, coordinating fire risk assessments, protecting compartmentation, managing building changes and maintaining fire protection systems are essential parts of an effective management approach.
Fire safety should be treated as an ongoing management responsibility rather than a one-time compliance exercise. Regular reviews, suitable training, planned maintenance and cooperation between responsible persons help ensure that precautions remain appropriate as building use and occupancy change.
By adopting a structured whole-building approach, organisations can improve fire prevention, strengthen emergency preparedness and create safer environments for employees, residents, visitors and contractors.
Continue developing your fire safety knowledge
Explore our professional fire safety and risk assessment qualifications to develop relevant knowledge and support professional development in fire safety management.
Official Fire Safety Guidance and Further Reading
The following sources provide additional information for people responsible for fire safety in relevant premises. Always consult the current guidance and legislation applicable to your jurisdiction and building type.
- GOV.UK – Fire Safety Risk Assessment: Offices and Shops
- GOV.UK – Workplace Fire Safety: Who Is Responsible?
- Home Office – Guide for Persons with Duties Under Fire Safety Legislation
- Legislation.gov.uk – Regulatory Reform (Fire Safety) Order 2005, Article 22
- GOV.UK – Fire Safety in Purpose-Built Blocks of Flats
- GOV.UK – Residents’ Guide to Fire Safety in Blocks of Flats